![]() ![]() One UPS is named "UPS Network" and controls power to networking equipment, and the other UPS is named "UPS Server" and controls power to the computer monitoring both UPSes. The UPS devices used as examples below are two APC SmartUPS SUA1500 devices connected to one computer via USB. In order to control multiple UPS devices, extra steps must be taken that are not required for monitoring only one UPS.įor multiple UPS monitoring to work, each UPS must be uniquely identifiable and uniquely named on the monitoring computer, separate nf files must be used for each UPS device, and a modified apcupsd init.d script must be used to control multiple apcupsd daemon processes. The following configuration steps can be used for monitoring one or more UPS devices from one computer. The log file /var/log/apcupsd.events says if the daemon has started correctly. Now you can start the daemon with the command: UPSTYPE : the type of UPS you have (USB, RS232,…)Īnd in /etc/default/apcupsd, you indicate that the configuration is done (not needed with systemd). UPSCABLE : the type of cable connecting the UPS to your computer. ![]() ![]() In /etc/apcupsd/nf, you must specify the type of UPS: The daemon controls and monitors the status of UPS and allows your computer to run for a specified length of time on UPS power, and then executes a controlled shutdown in the case of an extended power failure.īefore starting the daemon, you must at minimum configure /etc/apcupsd/nf and /etc/default/apcupsd. To see if your ups is recognized, use the command:īus 001 Device 002: ID 051d:0002 American Power Conversion Back-UPS Pro 500/1000/1500 The documentation is available in the apcupsd-doc package. The APC RBC batteries that are supplied with(in) a UPS will not have a dedicated Serial Number sticker, however they will always have a label marking them as Genuine APC shown below.Install the apcupsd package. Using of a non-APC battery will void APC’s Equipment Protection Policy.ĪPC provides a 1-year warranty on each RBC.ĪPC supplies the appropriate instructions, wires and connectors. Using of a non-APC battery may result in lower runtime, damage the UPS, create hazardous conditions, or void safety certifications on the UPS. Customers may wish to clarify why APC recommends using only genuine APC RBC in their UPS rather than 3rd party batteries with similar specifications, and may also wish to find out how to differentiate between a genuine APC RBC and a 3rd party battery.Īll APC UPS models using RBC type batteries. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |